Home > Unix Error > Unix Error Return Code Is 0139

Unix Error Return Code Is 0139

To animate the application, enter: new-run-time program-name where new-run-time is the name of the re-linked run-time and program-name is the name of the application. These are as follows: Banner information As COBSQL starts, it displays three banner lines which include the COBSQL version number. There can be many events which may have resulted in the system files errors. Note: If required, once you have set up the CSQLMakefile correctly, you can use Publisher to automate this step. his comment is here

It indicates that COBSQL has encountered the Working Storage Section and is about to process it. CSQL-F-012: INFORMIXDIR must be set for Informix Support To be able to use the Informix Precompiler, the environment variable INFORMIXDIR must be set. It is also possible to configure cob and add the .pco and .eco extensions to the list of default file extensions. I found a few references here and here from the frivolous to the serious[reply] Re: Re: return code 139 by riffraff (Pilgrim) on Mar 04, 2002 at 15:40UTC If the error my response

Publish the project. To unlock all features and tools, a purchase is required. The makefile to recreate the COBOL runtime is provided with the database precompiler. Is giving my girlfriend money for her mortgage closing costs and down payment considered fraud?

  • The corrupted system files entries can be a real threat to the well being of your computer.
  • To test for a segmentation fault, check $?
  • Shutting down the Toolbox environment or the Object COBOL Development Environment Menu System, and restarting should clear the problem.
  • in 139) echo "segfault occurred";; esac' EXIT In bash or ksh or zsh, you don't need to use set -e to execute a trap after each command that returns a nonzero
  • CSQL-E-024: Encountered an I/O on file This message is displayed when a write error occurs on either the trace or the debug file.

It also extracts the precompiler error number and text and attempts to locate the source line on which the error occurred. CSQL-F-009: Irrecoverable error in -- Terminating The Integrated Preprocessor that COBSQL invoked has returned a fatal error message. This is common error code format used by windows and other windows compatible software and driver vendors. This message is displayed if COBSQL receives a COBOL error while trying to write out a record to the STK side file.

Unix & Linux Stack Exchange works best with JavaScript enabled How to fix Unix Error Return Code Is 0139 Error? Disclaimer: This website is not affiliated with Wikipedia and should not be confused with the website of Wikipedia, which can be found at Wikipedia.org. These should be used to relink the COBOL run-time incorporating the database support modules. COBSQL reads the settings of the run-time switches and attempts to change the settings of the relevant switches in order to enable it to read code containing null characters.

Note: This article was updated on 2016-10-25 and previously published under WIKI_Q210794 Contents 1.What is Unix Error Return Code Is 0139 error? 2.What causes Unix Error Return Code Is 0139 error? CSQL-I-017: Creating COBSQL displays this message, for information only, when the expanded source file is to be kept. What does this 139 mean. Note: To be able to re-link the COBOL run-time a version of the "C" development system must be available on the machine.

Install the client software on both the PC and the UNIX deployment system. get redirected here There are two possible reasons for this. Compatibility: Windows 7, 8, Vista, XP Download Size: 6MB Requirements: 300 MHz Processor, 256 MB Ram, 22 MB HDD Limitations: This download is a free evaluation version. COBSQL needs to process copy statements that are inserted by the database precompiler.

These areas include Working-Storage, Procedure Division and SQL statements. http://fullflash.net/unix-error/unix-error-code-256.html What causes Unix Error Return Code Is 0139 error? Prepare a new COBOL run-time system on the UNIX platform by linking in database libraries. To override the default extension, use the -k option before the filename.

The files are copied to the UNIX system, and a Makefile created, but the application is not rebuilt. Configure the Publisher as required for this project (see the chapter Publisher Set-up for details on setting-up Publisher). Click UNIX, Setup. weblink Refer to the section on cob in your documentation for more details.

If the COBSQL "Verbose" or "Display" directives are used, then COBSQL will display this information. In some cases the error may have more parameters in Unix Exec Error Return Code Is 0139 format .This additional hexadecimal code are the address of the memory locations where the See the installation instructions for the database server for details.

share|improve this answer edited Nov 10 '11 at 12:26 answered Nov 10 '11 at 12:11 sr_ 11.3k2030 Something weird happens.

and those signal specs that lead to bash: trap: XX: invalid signal specification). –sr_ Nov 11 '11 at 9:34 add a comment| up vote 4 down vote trap "$instructions" SIGSEGV traps See the Database Access (DBpubb02.htm) book for more information on how to invoke COBSQL under NetExpress. Reserved Keywords DataDirect ODBC Drivers Appendix B: COBSQL Error Messages COBSQL displays four different types of message. The normal way to include database support is to re-link the COBOL run-time to create a new run-time.

This message is also displayed if the wrong Informix COBSQLTYPE is specified for the COBOL release that COBSQL is running with. Compatibility: Windows 7, 8, Vista, XP Download Size: 6MB Requirements: 300 MHz Processor, 256 MB Ram, 22 MB HDD Limitations: This download is a free evaluation version. Can the editor of a book add citations of individual chapters to his own citation count? check over here The most likely cause of this problem is that not enough memory is available or that too many virtual heaps have already been created.

The solution is to close down some COBOL applications to free up memory or virtual file slots. There are two (2) ways to fix Unix Exec Error Return Code Is 0139 Error: Advanced Computer User Solution (manual update): 1) Start your computer and log on as an About Us Contact us Privacy Policy Terms of use How to fix Unix Exec Error Return Code Is 0139 Error? What causes Unix Exec Error Return Code Is 0139 error?

This article contains information that shows you how to fix Unix Exec Error Return Code Is 0139 both (manually) and (automatically) , In addition, this article will help you troubleshoot some In some cases the error may have more parameters in Unix Error Return Code Is 0139 format .This additional hexadecimal code are the address of the memory locations where the instruction(s) You can, however, use the exitcode, stored in $?, in some conditional, and trap SIGCHLD: trap 'if [[ $? -eq 139 ]]; then echo "segfault !"; fi' CHLD Note that set If COBSQL cannot determine the severity of the error passed by the precompiler, it will assume that it is a normal error, rather than a fatal error.

So, for example, to set the COBSQL directive: COBSQLTYPE=ORACLE enter: COBSQLTYPE==ORACLE This only applies to directives placed on the cob command line. COBSQL attempts to open the source file before it invokes the database precompiler. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed This website should be used for informational purposes only.

This message is displayed if COBSQL has successfully read the run-time switches but has failed in its attempt to set them. The following is from perldoc -f system: You can check all the failure possibilities by inspecting `$?' like this: $exit_value = $? >> 8; $signal_num = $? & 127; $dumped_core = Either the directive is incorrect or the value supplied for the directive is incorrect.